Biodegradability Tests to
Protect the Environment
OPPTS
835.3110(m) and OECD 301B
Biodegradability
tests were performed in accordance with OPPTS
835.3110(m) and OECD 301B. In one case
natural inoculum was used and in the other
a commercial
inoculum (Polyseed) was used.
Test Results
Flame Guard Gel with OPPTS 835.3110(m) was 62%
biodegraded and with OECD 301B was 66 %
biodegraded in 28 days. These tests were
preformed with a mixture ratio of 1 pound of
Flame Guard Gel Powder to 1.7 gallons of water
(1 to 1.7).
USFS has classified Flame Guard
Gel as:
“Readily
Biodegradable.”
Actual use of Flame Guard Gel as a retardant
would not be a ratio of 1 lb to 1.7 gallons.
Instead it would be from a mixture ratio of from
1 lb to 5 gallons up to 1 lb, to 8 gallons.
FLAME GUARD GEL . . 66% IN 28 DAYS -
READILY BIODEGRADABLE
THERMO GEL . .
. . . . . 45% AT 42 DAYS - BIODEGRADABLE
NO CHAR . . . . . .
. . . . . 25% AT 42 DAYS MAXIMUM– NOT
BIODEGRADABLE
NO FIRE ICE . . . .
. . . . .13 % AT 21 DAYS MAXIMUM– NOT
BIODEGRADABLE
Fish Toxicity Tests to
Protect the Environment
The test results -
96 hours LC 50>
1000 mg/L
for rainbow trout
(60 days past hatching) in ASTM in soft water
LC50 is the concentration of an agent in water,
expressed as milligrams per liter of solution,
that results in the death of 50 percent of
aquatic test specimens within a specified time
frame.
In the case of
these tests, the exposure is 96 hours. The
fish, and the agent, are exposed in ASTM soft
water. This is simply a standard amount of
defined
chemicals added to distilled water so that it is
consistent regardless of who is doing the test.
Test
Results: Acceptable
Note:
Based on the
requirements in the USFS specification, Flame
Guard Gel with a ratio of .6 lbs to 1 gallon of
water (or 1 lb to 1.7 gallons) had acceptable
performance.
This ratio is
very severe since the working application ratio
of Flame Guard Gel would be more in the order of
1 lb to 8 gallons.
FLAME GUARD GEL .
. . .1000 MG/L - ACCEPTABLE
THERMO GEL .
. . . . . . . .28
MG/L - ACCEPTABLE
NO CHAR E-112 . . .
. . . . 61 MG/L - 38 MG/L ACCEPTABLE
NO FIRE ICE . . . .
. . . . . NO REPORT
This means it will
take 1000 milligrams of Flame Guard Gel at a
ratio of 1 to 1.7 in one liter of water to kill
50% of the rainbow trout in 96 hours. Higher
ratios, 1 to 5, 1 to 6, 1 to 8 will take more
than 1000 Milligrams of Flame Guard Gel.
Mammalian Toxicity Tests
To Protect Humans
Test Results
Acute Oral
Toxicity - Concentrate - Required >500 mg/Kg –
Performance
>5050mg/Kg
USFS: Acceptable
FLAME GUARD GEL . .
. . .
Performance >5050mg/Kg
THERMO GEL . . . . .
. . . . . Performance>5000 mg/Kg
NO CHAR E112 . . .
. . . . . .Performance>5050 mg/Kg
NO FIRE ICE . . . .
. . . . . . . Performance>5050 mg/Kg
Acute Oral Toxicity- Mixed
Fire Chemical - Required >5000mg/Kg
Performance
>5050mg/Kg
USFS:
Acceptable
FLAME GUARD GEL .
. . . .
Performance >5050mg/Kg
THERMO GEL . . . . . . . . . . Performance
>5000mg/Kg
NO CHAR E112 . . .
. . . . . Performance>5050 mg/Kg
NO FIRE ICE . . . .
. . . . . . . Performance>5050 mg/Kg
Acute Dermal Toxicity - Concentrate – Required
>2000mg/Kg
Performance
>2020mg/Kg
USFS:
Acceptable
FLAME GUARD GEL .
. . . .
Performance >2020mg/Kg
THERMO GEL . . . . . . . . . . Performance
>2020mg/Kg
NO CHAR E112 . . .
. . . . . Performance>2020 mg/Kg
NO FIRE ICE . . . .
. . . . . . . Performance>2020 mg/Kg
Acute Dermal Toxicity -Mixed Fire Chemical–
Required >2000mg/Kg
Performance
>2020mg/Kg
USFS:
Acceptable
FLAME GUARD GEL .
. . . .
Performance >2020mg/Kg
THERMO GEL . . . . . . . . . . Performance
>2020mg/Kg
NO CHAR E112 . . .
. . . . . Performance>2020 mg/Kg
NO FIRE ICE . . . .
. . . . . . . Performance>2020 mg/Kg
Primary Eye
Irritation–Unwashed Eyes-Concentrate-
Required -
Mildly irritating
Performance –
Practically non-irritating
USFS: Acceptable
– Toxicity category IV
Irritation score 0.7
FLAME GUARD GEL .
. . . .
Practically non-irritating Irritation score 0.7
THERMO GEL . . . . . . . . . .
Severely irritating Irritation score 32.0
NO CHAR E112 . . .
. . . . .
Mildly irritating
Irritation Score 15.7
NO FIRE ICE . . . .
. . . . . . . Moderately irritating Irritation
Score 2.7
Primary Eye Irritation-Unwashed Eyes-Mixed Fire
Chemical
Required – Mildly irritating
Performance –
Mildly irritating
USFS:
Acceptable
– Toxicity category IV
Irritation Score 8.0
FLAME GUARD GEL .
. . . .
Mildly irritating -
Irritation Score 8.0
THERMO GEL . . . . . . . . . .
Practically non-irritating Score 1.7
NO CHAR E112 . . .
. . . . . Minimally irritating Score 3.3
NO FIRE ICE . . . .
. . . . . . .
Practically
non-irritating Score 0.3
Primary Eye Irritation-Washed Eyes-Concentrate
Required –
Mildly irritating
Performance –
Minimally irritating
USFS:
Acceptable –
Toxicity category IV
Irritation Score 1.3
FLAME GUARD GEL .
. . . .
Minimally irritating
Irritation Score
1.3
THERMO GEL . . . . . . . . . .
Mildly irritating Irritation Score 15.3
NO CHAR E112 . . .
. . . . .
Mildly irritating
Irritation Score 8.7
NO FIRE ICE . . . .
. . . . . . . Minimally irritating Irritation
Score 2.7
Primary Eye Irritation-Washed Eyes-Mixed Fire
Chemical
Required –
Mildly irritating
Performance
–Mildly irritating
USFS: Acceptable
–
Toxicity category IV
Irritation
Score 17.3
FLAME GUARD GEL .
. . . .
Mildly irritating Irritation Score 17.3
THERMO GEL . . . . . . . . . .
Non irritating Irritation
Score 0.0
NO CHAR E112 . . .
. . . . . Practically non irritating Score 0.7
NO FIRE ICE . . . .
. . . . . . . Minimally irritating Irritation
Score 3.3
Primary Dermal Irritation
Concentrate-Required- Mildly irritating Score
<5.0
Performance-Score 0.8 Slight irritant
USFS:
Acceptable –
FLAME GUARD GEL .
. . . .
Slight irritant Score 0.8
THERMO GEL . . . . . . . . . .
Slight irritant Score 0.6
NO CHAR E112 . . .
. . . . .
Moderate irritant Score 2.2
NO FIRE ICE . . . .
. . . . . . . Non-irritating Score 0.0
Primary Dermal Irritation Mixed Fire Chemical
Required-Mildly
irritating Score <5.0
Performance-Score 0.8 Slight
irritant
USFS:
Acceptable –
Based
upon the satisfactory test results a review
by the Forest Service Safety and Health
Branch was not required.
FLAME GUARD GEL .
. . . .
Slight irritant Score
0.8
THERMO GEL . . . . . . . . . . Slight
irritant Score 0.2
NO CHAR E112 .
. . . . . . . Slight irritant Score 0.2
NO FIRE ICE . .
. . . . . . . . .
Non-irritating
Score 0.0
Cleveland Open
Point Flash Point
Tests for
Product Performance
Test
results:
did not produce a flash point or a fire
point.
USFS Rated: Acceptable
Performance.
Flash Point is the minimum
temperature of a product at which it gives off
vapor sufficient to form an ignitable mixture of
a gas near the surface of
the liquid under specified environmental
conditions.
As you heat a product if gives off vapors some
of which may be flammable.
The flash point is the
temperature when enough of the flammable gases
are produced to
actually generate a momentary flame.
The open cup part means that this test is
performed in the open environment
rather than a closed system.
The safety issues
here are that these products are used when it is
very hot
and they are often poured, transferred, or used
near hot engines. If a
product has a low flash point the potential is
greater for accidents and
injury as the product gives off flammable vapor.
FLAME GUARD GEL .
. . . .
Did
not produce a flash point or a fire point.
THERMO GEL . . . . . . . . . .
No data
NO CHAR E112 .
. . . . . . .
No data
NO FIRE ICE . .
. . . . . . . . .
No data
Lateral
Ignition and Flame Spread Tests
Tests For Product Performance
Underwriters
Laboratories Inc., performed fire tests for
Lateral Ignition and Flame
Spread (LIFT) under
contract with the U.S.Forest Services.
Test results
Using UL Standard UL
1321 Flame Guard Gel offered significant
resistance before the second layer of the
substrates ignited. The top layer charred with
no visible flames. Instead the second layer
ignited at 42 and 50 minutes through the cracks
in the top layer. The performance of Flame Guard
Gel as a retardant was far superior to foams and
elastomers and superior to other gels tested.
The USFS conducts this test for
informational purposes only.
FLAME GUARD GEL .
. . . .
(23) NO
IGNITION OVER 42 and 50 MINUTES.
THERMO GEL . . . . . . . . . .
(14) 10.00
– 18.35 – 14.05 – 27.52 MINUTES
NO CHAR E112 .
. . . . . . . NO TEST
NO FIRE ICE . .
. . . . . . . . .
( 1 ) IGNITION AT
28.04 – 33.30 – 42.40 Minutes
Final
Corrosion Tests
by 90-day Weight Loss Test
FGG Material
Tested with Mixture 0.6 lbs/ 1 gallon of water
After one-year
storage of Mixture
2024-T3
Aluminum,
Aluminum Corrosion Test Results
Aluminum Total Immersion 70F
FGG. . . . . . .
. . . . . . . . . . 0.3 mils per year
NO CHAR
(FRESH) . . . . . .0.1
NO CHAR
(3%) . . . . . . . . 0.1
THERMO GEL
(MISS) . . . . .0.11
THERMO GEL (SD)
. . . . . . 0.10
FIRE OUT ICE
(0.6%) . . . . . 0.51
Aluminum Total
Immersion 120F
FGG
. . . . . . . . . . . . . . . . 0.1 mils per year
NO CHAR
(FRESH) . . . . . . 0.1
NO CHAR
(3%) . . . . . . . . . 0.1
THERMO GEL
(MISS) . . . . . 0.25
THERMO GEL
(SD) . . . . . . 0.26
FIRE OUT ICE
(0.6%) . . . . . 1.90
Aluminum Partial
Immersion 70F
FGG . . .
. . . . . . . . . . . . . 0.3 mils per year
NO CHAR
(FRESH) . . . . . . 0.1
NO CHAR
(3%) . . . . . . . . . .0.1
THERMO GEL
(MISS) . . . . . 0.08
THERMO GEL
(SD) . . . . . . . .0.09
FIRE OUT ICE
(0.6%) . . . . . . 0.30
Aluminum Partial
Immersion 120F
FGG . . . . . .
. . . . . . . . . . . . .
0.1 mils per year
NO CHAR
(FRESH) . . . . . . . . 0.1
NO CHAR
(3%) . . . . . . . . . . . .0.1
THERMO GEL
(MISS) . . . . . . .0.13
THERMO GEL
(SD) . . . . . . . . 0.15
FIRE OUT ICE
(0.6%) . . . . . . .0.92
4130 Mild Steel
Corrosion Test
Results
Mild Steel
Total Immersion 70F
FGG . . .
. . . . . . . . . . . . . . 0.3 mils per year
NO CHAR
(FRESH) . . . . . . .0.1
NO CHAR
(3%) . . . . . . . . . . 0.1
THERMO GEL
(MISS) . . . . . .0.05
THERMO GEL
(SD). . . . . . . . 0.05
FIRE OUT ICE
(0.6%) . . . . . . 0.51
Mild Steel Total
Immersion 120F
FGG
. . . . . . . . . . . . . . . . . 0.1 mils per year
NO CHAR
(FRESH) . . . . . . 0.1
NO CHAR
(3%) . . . . . . . . . .0.1
THERMO GEL
(MISS). . . . . .0.25
THERMO GEL
(SD) . . . . . . . 0.26
FIRE OUT ICE
(0.6%) . . . . . . 1.90
Mild Steel
Partial Immersion 70F
FGG . . . . . .
. . . . . . . . . . . .1.5 mils per year
NO CHAR -
FRESH . . . . . . . 0.1
NO CHAR –
3% . . . . . . . . . .0.1
THERMO GEL
(MISS) . . . . . .0.20
THERMO GEL
(SD) . . . . . . . .0.35
FIRE OUT ICE
(0.6%) . . . . . . 1.90
Mild Steel
Partial Immersion 120F
FGG . . . . . .
. . . . . . . . . . . .0.3 mils per year
NO CHAR
(FRESH) . . . . . . 0.1
NO CHAR
(3%) . . . . . . . . . . 0.1
THERMO GEL
(MISS) . . . . . .0.51
THERMO GEL
(SD) . . . . . . . 0.56
FIRE OUT ICE
(0.6%) . . . . . . 0.51
Yellow
Brass Corrosion Test Results
Yellow
Brass
Total Immersion
70F
FGG . . . .
. . . . . . . . . . . . .0.1 mils per year
NO CHAR
(FRESH) . . . . . . . 0.1
NO CHAR
(3%) . . . . . . . . . . 0.1
THERMO GEL
(MISS) . . . . . .0.1
THERMO GEL
(SD) . . . . . . . .0.05
FIRE OUT ICE
(0.6%) . . . . . . .0.51
Yellow
Brass
Total Immersion
120F
FGG
. . . . . . . . . . . . . . . . . . .0.1 mils per year
NO CHAR
(FRESH) . . . . . . . 0.1
NO CHAR
(3%) . . . . . . . . . . .0.1
THERMO GEL
(MISS) . . . . . . 0.14
THERMO GEL
(SD) . . . . . . . .0.16
FIRE OUT ICE
(0.6%) . . . . . . .1.90
Yellow
Brass
Total Immersion
70F
FGG . . . . . .
. . . . . . . . . . . . 0.2 mils per year
NO CHAR
(FRESH) . . . . . . . 0.1
NO CHAR
(3%) . . . . . . . . . . 0.1
THERMO GEL
(MISS) . . . . . . 0.08
THERMO GEL
(SD) . . . . . . . . 0.04
FIRE OUT ICE
(0.6%) . . . . . . .0.51
Yellow
Brass
Total Immersion
120F
FGG
. . . . . . . . . . . . . . . . . .0.3 mils per year
NO CHAR
(FRESH). . . . . . . . 0.1
NO CHAR
(3%). . . . . . . . . . 0.1
THERMO GEL
(MISS). . . . . . .0.13
THERMO GEL
(SD). . . . . . . .0.10
FIRE OUT ICE
(0.6%). . . . . . .1.90
Initial
Corrosion Tests
by 90-day Weight Loss Test
Tested with
Mixture 0.6 lbs/ 1 gallon of water
Material Tested: 2024-T3 Aluminum
Yellow Brass.
FLAME GUARD GEL. . . . . .
USFS classified results as
ACCEPTABLE-
THERMO GEL . .
. . . . . . . . Not Tested
NO CHAR . . . . . .
. . . . . . . . Not Tested
NO FIRE ICE
. . . . . . . . . . . . Not Tested
|